0409-bafu-water-in-cubic-metres met
- Issue
- #409
- Stated in
- expectations/0409-bafu-water-in-cubic-metres.json
- Graded against
- Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).
Why this file exists
Liquid water is published in cubic metres throughout this list -- every one of the eleven flows carrying EF 3.1's Water use factors, and every water resource ecoinvent ships. BAFU measures sixteen of its water rows by mass, and nine water rows ended up landing on a flow stating the other unit: a kilogram row on a cubic-metre flow, or a cubic-metre row on a kilogram flow BAFU's own kilogram rows had minted. Stating the density and carrying the rows in cubic metres settles both directions. The one crossing left runs the other way -- BAFU states the volume of sea water and EF 3.1 states its mass -- and is accepted with the factor ecoinvent's identical row already carries. See #78, and #89 for the compartment half of the same work.
Expectations
3| What should be true | State | About |
|---|---|---|
|
The kilogram of water BAFU discharges to a river reaches the river, like its 53 siblings
0409-bafu-water-to-a-river-reaches-the-river
The row this change started from. BAFU ships 53 regionalised cubic-metre rows and one unregionalised kilogram row into this compartment; the kilogram row could not reach the flow the other 53 reach, because the only water flow in |
met |
source_row
list: bafu
name: Water
context: ["emissions to water","river"]
|
|
No BAFU water row lands on a flow measured in another unit, except the one that runs the other way
0409-bafu-liquid-water-does-not-cross-a-unit
179 on the build before this change, of which 9 were water. Eight of the nine are BAFU measuring by mass what the list measures by volume, and are converted at 1000 kg/m3. The ninth is sea water and is not a defect of BAFU's: EF 3.1 accounts sea water by mass, BAFU and ecoinvent both by volume, and ecoinvent's identical row is already accepted with the factor stated -- so this one is accepted the same way and stays in the count. A bound rather than a row claim, because the 170 rows this does not touch are radionuclides in Bq against kBq, which is #78's other half and another change's work. |
met |
measure
key: merge.bafu-2026-v1.unit_mismatch
|
|
The kinds of water only BAFU reports are published in cubic metres too
0409-bafu-waste-water-is-published-in-cubic-metres
Waste water, contaminated water and surface water have no counterpart in EF 3.1 or ecoinvent, so nothing outside BAFU forces a measure on them and BAFU wrote two of waste water's three rows by mass. A flow's unit should not be an accident of which vendor row happened to mint it -- the argument #67 accepted for standing wood. Waste water is named here because it is the one of the three with more than one flow, so a change that converted only the first would still fail. |
met |
flow
name: Waste water
|