0599-trichloroethane-isomers met
- Issue
- #599
- Stated in
- expectations/0599-trichloroethane-isomers.json
- Graded against
- Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).
Why this file exists
1,1,1-trichloroethane is the degreasing solvent banned under the Montreal Protocol for eating ozone; 1,1,2-trichloroethane is a suspected carcinogen with no effect on ozone at all. They differ in which carbon one chlorine sits on. EF 3.1 ships five flows -- the five air compartments -- named 1,1,1-trichloroethane that carry 79-00-5, which is 1,1,2's registry number, 1,1,2's synonyms and 1,1,2's toxicity factors; 1,1,2's remaining eight compartments are named correctly, and the two sets do not overlap. The real 1,1,1-trichloroethane is in EF twice, as hcfc-140 (thirteen compartments) and methyl chloroform (four), and never under its own name. This project trusts the registry number, so the five mislabelled flows merge into published 1,1,2-trichloroethane and the solvent is published from hcfc-140 -- the right call on the evidence. The damage is downstream of it: ecoinvent's correspondence table maps by flow identifier, and the identifiers still point where EF's names sent them, so nine of ecoinvent's nineteen 1,1,1-Trichloroethane rows -- every emission to air -- are published as 1,1,2-trichloroethane while its ten emissions to water are published correctly. One ecoinvent substance, split by compartment across two published substances, and the half that moves is the half that matters for an ozone-depleting solvent. See #121.
Something found beside it is deliberately not claimed here: seven of ecoinvent's own 1,1,2-Trichloroethane air rows are sent to Hydrocarbons, Chlorinated, the unnamed catch-all, in the same compartments -- so in air the two isomers have swapped places and one has vanished into a bucket. That half belongs to the #76 family and is left to it.
Expectations
3| What should be true | State | About |
|---|---|---|
ecoinvent's 1,1,1-Trichloroethane rows all reach one published substance
0599-one-substance-not-two
In the build of 20 August 2026 at 1764991 (merging ecoinvent 3.12 and 3.8) the nineteen rows reach two substances: the nine emissions to air reach 1,1,2-trichloroethane and the ten emissions to water reach the solvent itself. Every one of the nineteen carries 71-55-6, so this is one ecoinvent substance split by compartment, which is the shape of #45. Selected by name rather than by number because the number is what is right about these rows and a selector should name what will still be findable; the name is stable in every release this build merges -- 3.9.1 alone spells it |
met |
source_row
list: ecoinvent
name: 1,1,1-Trichloroethane
|
ecoinvent's 1,1,1-Trichloroethane rows are published as 1,1,1-trichloroethane
0599-the-air-rows-reach-the-solvent
The half that says which of the two substances the split should collapse onto, and the one the fix is measured by. Nine rows fail it in the build above -- four from 3.12 and five from 3.8, all emissions to air -- because the prepared table sends them to the EF flows named |
met |
source_row
list: ecoinvent
name: 1,1,1-Trichloroethane
|
|
This list does not publish an ozone-depletion factor for 1,1,2-trichloroethane
0599-the-carcinogen-carries-no-ozone-factor
Recorded, not fixed, and the third thing #121 asks for. This list publishes an ozone-depletion factor of 0.14 on 1,1,2-trichloroethane -- ten rows in the build above, the five air compartments under the JRC's implementation and again under this list's -- for a substance that depletes no ozone. It is there because the five EF flows carrying the factor carry 79-00-5. Two things say the number is 1,1,1-trichloroethane's: every one of the other 24 substances EF gives an ozone-depletion factor is a genuine ozone depleter -- CFCs, halons, bromomethane, carbon tetrachloride -- and 1,1,2-trichloroethane is controlled by nothing and has no ODP anywhere. So EF appears to have assigned this one factor by the flow's name while assigning the toxicity factors by its registry number, which means its ozone-depletion method and its toxicity methods disagree about which chemical the flow is. The mirror fact is that no flow carrying 71-55-6 has an ozone-depletion factor at all, so the solvent is published without its signature effect; that cannot be written as a second expectation, because a selector matching nothing reports |
met |
factor
substance_cas: 79-00-5
category: Ozone depletion
implemented_by: brightway-flows
|