0671-the-tables-are-retired met
- Issue
- #671
- Stated in
- expectations/0671-the-tables-are-retired.json
- Graded against
- Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).
Why this file exists
ecoinvent's prepared correspondence tables are retired (#141, plans/retire-prepared-correspondence.md): every ecoinvent row is now decided by this project's own matching, the element/ion rule (§3a), and the curated rows in ecoinvent-match-overrides.json. These claims pin the retirement's load-bearing outcomes: the #130 twins resolve onto the substances their own registration names; the element/ion rule's landings hold in every compartment; the origin-qualifier wall held where ecoinvent marks the qualifier by uuid alone; the joins the table used to carry (heat, the buckets, the size fractions) survive as this project's stated rows; and the ore conversion this project already ruled on still converts. Measured on the retirement build of 2026-08-23. The factor movements are the flows' movements: no factor changed its value on a flow that stayed put, but flows that moved took and surfaced factors -- factors_published shifts by a few dozen in six hundred and seventy thousand, and the proposed-factor queue grows from 132 to 204 because flows the tables had hidden behind wrong matches now ask their own factor questions.
Expectations
9| What should be true | State | About |
|---|---|---|
|
ecoinvent's metaldehyde lands on the metaldehyde the JRC characterised
0671-metaldehyde-reaches-the-characterised-twin
The #130 twin: with the table retired the rows follow their own registration, 108-62-3, to the entry carrying the JRC's factors, instead of EF's uncharacterised duplicate (9002-91-9). The substance is the claim: one row lands on a factorless duplicate *flow* of the right substance, and joining the twin objects flow-by-flow is #130's work, not the retirement's. |
met |
source_row
list: ecoinvent
name: Metaldehyde
|
|
ecoinvent's fenpropimorph is one substance in 3.8 and 3.12 alike
0671-fenpropimorph-reaches-one-substance-in-both-releases
The #130 twin plus a stale 3.8 registration: 3.12 registers the racemate 67564-91-4 and 3.8 registered the skeleton, so without the manual fix the retirement would split one fungicide by release. |
met |
source_row
list: ecoinvent
name: Fenpropimorph
|
|
Nickel II is nickel(2+) in air and soil, not only in water
0671-nickel-ii-is-the-ion-in-every-compartment
Plan §3a clause 2: the name decides, charge-normalised, in every compartment alike. The table used to send the air and soil rows to the element. |
met |
source_row
list: ecoinvent
name: Nickel II
|
3.8's Zinc, ion rows follow the newest release's identity to zinc(2+)
0671-bare-zinc-follows-its-canonical-identity
Rewritten on #398, keeping the id: the five rows this selects are 3.8's |
met |
source_row
list: ecoinvent
version: 3.8
name: Zinc II
|
|
Copper ion lands on a generic copper-ion substance, not on the element and not on a guessed charge
0671-the-generic-ion-is-its-own-substance
§3a clause 4: 3.12 deleted the number deliberately, and picking Cu(2+) for it would be the reinterpretation the rule refuses. The object is minted, on the |
met |
source_row
list: ecoinvent
name: Copper ion
|
|
ecoinvent's land-use-change methane stays on the land-use-change substance
0671-the-qualifier-wall-held
ecoinvent marks the qualifier by uuid alone -- the row is named plain |
met |
source_row
list: ecoinvent
uuid: 9541a975-800f-4fed-9edf-28f6e411a015
|
|
ecoinvent's waste heat is EF's waste heat, not a second heat
0671-the-heat-join-survives
Heat has no registry number, so the name join the table used to carry is stated in ecoinvent-match-overrides.json; without it the retirement shadow build minted a duplicate substance for all 27 rows. |
met |
source_row
list: ecoinvent
name: Heat, Waste
|
|
Every TiO2-in-ore spelling converts to elemental titanium at the stated factor
0671-the-ore-conversion-still-converts
The 0.599 kg/kg conversion this file has carried since #260 -- plus the fourth sibling spelling, which the shadow build showed landing unconverted on titanium dioxide while its three siblings converted. |
met |
source_row
list: ecoinvent
name_contains: TiO2
|
|
The five minted generic-ion substances share one spelling
0671-a-minted-ion-has-one-spelling
The follow-up named on #141 as minted-ion label harmonisation. The creation path took whichever vendor spelling arrived first, so five substances of one shape (Antimony, Arsenic, Copper, Iron, Tin) published as |
met |
substance
label: Antimony, Ion
|