Brightway Flows 1.2.0
GitHub
Issue
#724
Stated in
expectations/0724-one-substance-one-climate-number.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

Three substances carried two climate numbers apiece, or none, because the JRC's EF 3.1 and ecoinvent's implementation of it read IPCC AR6 differently. Two of those splits are one number printed twice -- AR6's Chapter 7 Table 7.15 assesses CFC-11 at 6226 ±2297 and HFC-134a at 1526 ±577, and the supplementary Table 7.SM.7 rounds them to 6230 and 1530 -- so lcia-rounded-printings.json publishes the precise value in the two compartments where only the rounded transcription had a flow. The third is not: AR6 assesses sulfur hexafluoride with a 3200-year lifetime and prints 25200, ecoinvent's 24300 is that radiative efficiency with a lifetime near 1000 years, and a ruling publishes the method's own publisher's number. After both, each substance states one number in every compartment it is published in. See #342.

Since #459 the ecoinvent Centre is read twice, and both of its workbooks decide. The 3.12 workbook still states 24,300 for SF6 and Chapter 7's 6,226 and 1,526; the 3.13 workbook states AR6's 25,200 and the supplement's 6,230 and 1,530, as the JRC does. Neither changes an answer here: SF6 is still a disagreement between publishers, now asked by three implementations, and the ruling records all three; CFC-11 and HFC-134a still agree within tolerance where ecoinvent has a flow, the more precise 6,226 and 1,526 are kept, and the four printings still refine the two compartments only the JRC has. The 3.13 workbook is closed, so its numbers are not published under its name, which the last claim here holds.

Expectations

9
What should be true State About
An SF6 emission to unspecified air is characterised at all
0724-sulfur-hexafluoride-is-worth-something-in-unspecified-air

The compartment an inventory writes to when it does not say where the emission went, and the one the disagreement blocked: before the ruling this list published nothing here, so the most potent greenhouse gas either implementation characterises scored zero. 25200 is AR6 Table 7.SM.7's own GWP100, which is the table EF 3.1's climate category names.

met factor
flow_name: Sulfur hexafluoride
context_display: Environmental → Air → Unknown
category: Climate change
implemented_by: brightway-flows
The same emission is characterised under Climate change-Fossil
0724-and-in-the-fossil-sub-category

Both queue items are ruled, so both are claimed. A ruling on the aggregate and not on the sub-category that adds up to it would publish a substance into one and not the other.

met factor
flow_name: Sulfur hexafluoride
context_display: Environmental → Air → Unknown
category: Climate change-Fossil
implemented_by: brightway-flows
The compartment where only the JRC speaks states the same number as the rest
0724-sulfur-hexafluoride-states-one-number-everywhere

ecoinvent has no flow here, so this row was never blocked and never changed: it published 25200 before the ruling and after it. Claimed anyway, because the point of the ruling is that the substance now carries one number in all six air compartments, and that is only true if this one still agrees with the four the ruling filled. Its derivation stays sole -- nobody contested it here.

met factor
flow_name: Sulfur hexafluoride
context_display: Environmental → Air → Aircraft cruise height
category: Climate change
implemented_by: brightway-flows
The ecoinvent Centre's 3.12 workbook's 24,300 is still published under its own name
0724-ecoinvent-still-states-its-own-number

A ruling picks what this list publishes and erases nobody. ecoinvent's number reflects a shorter atmospheric lifetime than AR6 assessed, which is probably the better science and is certainly the newer; a practitioner who wants it can see it here and say so in their assessment.

met factor
flow_name: Sulfur hexafluoride
context_display: Environmental → Air → Unknown
category: Climate change
implemented_by: ecoinvent Centre (3.12)
CFC-11 is worth 6,226 in every air compartment, not 6,230 in two of them
0724-cfc-11-is-one-number-at-cruise-height-too

One of the two compartments ecoinvent has no flow for, where the JRC's rounded transcription used to go out unopposed. derivation: refined rather than sole says a curated printing acted, and points at the file that cites the two AR6 tables.

met factor
flow_name: Trichlorofluoromethane
context_display: Environmental → Air → Aircraft cruise height
category: Climate change
implemented_by: brightway-flows
HFC-134a is worth 1,526 indoors, as it is everywhere else
0724-hfc-134a-likewise

The refrigerant, and the other of the two substances AR6 prints twice. Indoor air rather than cruise height, so that both of the compartments the refinement reaches are claimed across the two substances.

met factor
flow_name: 1,1,1,2-Tetrafluoroethane
context_display: Environmental → Air → Indoor
category: Climate change
implemented_by: brightway-flows
The JRC's implementation still states 6,230 for CFC-11
0724-the-jrc-still-prints-what-the-supplement-prints

The transcription is not touched. 6230 is exactly what Table 7.SM.7 prints, the JRC transcribed it correctly, and a reader comparing this list against EF 3.1 has to see the difference rather than have it quietly reconciled -- the stance the moved-factor and contradicted-factor machinery already takes.

met factor
flow_name: Trichlorofluoromethane
context_display: Environmental → Air → Aircraft cruise height
category: Climate change
implemented_by: European Commission — JRC
Eight factors are refined, and not one more
0724-only-the-two-documented-substances-are-refined

Two substances, two categories, two compartments each. Claimed exactly rather than bounded below, because the guardrail is the count: 97 (substance, category) groups on this build publish two values agreeing within 2%, and 93 of them are freshwater ecotoxicity where the two values are two compartments' own numbers. A refinement that grew past eight without a curator adding a cited row would be this file having become a tolerance rule.

met measure
key: factors.ef_rounded_printings_refined
value_when_absent: 0
The ecoinvent Centre's 3.13 workbook's 25,200 for sulfur hexafluoride is read and not published
0724-the-3-13-workbook-is-not-published

The 3.13 workbook decides -- its 25,200 is one of the three numbers the ruling above records -- and is closed: ecoinvent has published no 3.13 file, and the workbook's terms do not let this list republish it. So no factor of its is written under its name, here or anywhere (#459).

met factor
flow_name: Sulfur hexafluoride
context_display: Environmental → Air → Unknown
category: Climate change
implemented_by: ecoinvent Centre (3.13)

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close