0731-the-convention-carries-across-air met
- Issue
- #731
- Stated in
- expectations/0731-the-convention-carries-across-air.json
- Graded against
- Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).
Why this file exists
#152 found that a kilogram of sulphuryl difluoride from a rural stack was worth 4,630 kg CO2-eq and the same kilogram over a suburb was worth nothing, and answered it with a rule that carried one air factor across every air sub-compartment in three well-mixed categories, indoor and long-term air included. That rule is retired: data/context-carry-rules.json carries the outdoor strata from unspecified air in every category, and indoor and long-term air are walls nothing crosses. This file replaces 0731-one-air-factor-covers-every-compartment.json, whose indoor expectations it deliberately inverts.
Expectations
3| What should be true | State | About |
|---|---|---|
|
Sulphuryl difluoride released over a suburb is worth what it is worth from a stack
0731-the-fumigant-is-characterised-where-it-is-released
The expectation the first rule was written for, kept. The urban ground level takes unspecified air's number under the convention, and unspecified air carries the 4,630 a ruling published (#151). |
met |
factor
flow_name: Sulphuryl Difluoride
context_display: Environmental → Air → Ground level → Urban (>1000 people/square mile)
category: Climate change
implemented_by: brightway-flows
|
|
The same kilogram released indoors is not characterised
0731-but-not-indoors
Indoor air is a wall of the convention: a different fate model, and one convention has no per-category holes in a wall. The first rule carried fifteen indoor factors for HFCs and halons on the strength of the gas being well mixed; they are withdrawn with it, and whether a greenhouse gas should cross this wall is recorded as an open decision in |
met |
factor
flow_name: Sulphuryl Difluoride
context_display: Environmental → Air → Indoor
category: Climate change
implemented_by: brightway-flows
|
|
A high urban stack takes the rural stack's number
0731-a-high-stack-in-a-city-behaves-as-rural
The downward rules carry 1,515 factors for EF 3.1 on the 2026-09-01 build -- 1,029 rivers, 121 lakes, 170 silvicultural and 125 industrial soils, 30 non-agricultural soils, and 40 air strata -- and 8,257 for Stepwise. Bounded from below rather than pinned, because the count grows with every list that brings a context somebody else characterised; what must not happen is the pass going silent, which a thousand guards against. |
met |
measure
key: factors.ef_context_carry_carried_downward
value_when_absent: 0
|