0736-particulate-size-windows met
- Issue
- #736
- Stated in
- expectations/0736-particulate-size-windows.json
- Graded against
- Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).
Why this file exists
BAFU reports airborne particles under seven names. Three are size bands the list already publishes and land on them. The one reporting PM10 itself -- every particle below ten micrometres, which is what air-quality regulation and most inventories report -- landed on nothing and was published as a substance of its own with no characterisation factors at all. Meanwhile BAFU's *coarse band* rows, 2.5 to 10 micrometres, reached Particles (PM10) on an alternative label: ecoinvent's spelling of the coarse fraction, left on that flow by the member-name pass after #37's override put those rows in its merge group. So the flow named PM10 was fed by rows that are not PM10, and the rows that are PM10 were stranded beside it.
The fix gives the size window a field. A window is a pair of aerodynamic-diameter bounds, and the pair is the identity: Particulates, < 10 um and particles (PM10) state one window and meet on one flow with no crosswalk row, while Particulates, > 2.5 um, and < 10um states a different one and cannot arrive at PM10 by resembling it. Measured on the build of 25 August 2026, run 20260825T0605411116990000, revision b03c940b. See plans/particulate-taxonomy.md.
Expectations
12| What should be true | State | About |
|---|---|---|
|
The BAFU row reporting PM10 lands on the flow this list publishes for PM10
0736-bafu-pm10-reaches-pm10
On the 25 August build this row was |
met |
source_row
list: bafu
name: Particulates, < 10 um
|
|
That row now reaches a flow that something can characterise
0736-bafu-pm10-is-characterised
The point of the whole exercise, stated separately from where the row lands: landing on the right flow is only worth something if that flow carries factors. |
met |
source_row
list: bafu
name: Particulates, < 10 um
|
|
PM10 from a stationary source is still PM10
0736-bafu-stationary-pm10-reaches-pm10
|
met |
source_row
list: bafu
name: Particulates, < 10 um (stationary)
|
|
BAFU's coarse-fraction rows no longer reach the flow named PM10
0736-bafu-coarse-band-does-not-reach-pm10
Four rows, one per compartment. On the 25 August build all four matched |
met |
source_row
list: bafu
name: Particulates, > 2.5 um, and < 10um
|
|
The substance published as PM10 is the same substance it was before
0736-ef-pm10-keeps-its-identity
Giving the window a field is not a reason for the flow objects EF 3.1 already publishes to change identity. Six of the seven size classes declare the |
met |
substance
id: fo-4619792929f057e6
|
|
The coarse fraction is one substance, not a second copy of PM10
0736-the-coarse-band-is-published-once
The flow BAFU's coarse rows now reach. EF 3.1 gives it no characterisation factor in any compartment, so those rows still score zero -- but that is EF's answer about the coarse fraction rather than a mapping that says the coarse fraction is PM10. |
met |
substance
id: fo-ae1315a262379c68
|
|
The rows that state no particle size are one substance, not four
0736-the-size-unstated-total-is-one-substance
BAFU ships |
met |
substance
label: Particles (unspecified size)
|
|
The size-unstated total is published as a measurement, not as a class of molecules
0736-the-unsized-total-is-a-measurement-not-a-class-of-molecules
Found by building it. The six size bands EF 3.1 publishes are typed |
met |
substance
label: Particles (unspecified size)
|
Particulates and Particulates, unspecified reach the same substance
0736-both-unsized-names-reach-one-flow
Seven BAFU names over 17 rows, reaching five substances: PM2.5, the coarse band, above-PM10, PM10 (which three names now reach -- |
met |
source_row
list: bafu
name_contains: Particulates
|
|
ecoinvent's coarse-fraction rows reach the coarse band, like every other list's
0736-ecoinvent-coarse-band-decision-is-recorded
#37's trade, retired. It sent ecoinvent's 2.5-10 um rows to EF's |
met |
source_row
list: ecoinvent
name_contains: > 2.5 um
|
Particulates, > 2.5 um, and < 10um is a name for the coarse fraction, not for PM10
0736-the-coarse-fractions-name-belongs-to-the-coarse-fraction
On the 25 August build this name was an alternative label of |
met |
substance
label: Particles (PM2.5 - PM10)
|
|
EF 3.1 reaches six of the seven size windows, and mints an object for each
0736-every-size-window-is-reached
Six and not seven, and the missing one is the point rather than a gap: EF 3.1 publishes a flow for every size band it characterises and none at all for particles whose size was not stated. The seventh window, |
met |
measure
key: stats.resolve_flow_layers.size_class_object_count
|