Brightway Flows 1.2.0
GitHub
Issue
#749
Stated in
expectations/0749-water-vapour-is-declined.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

EF 3.1's Water use can be implemented two ways and both are right on their own. The JRC counts consumption as water withdrawn minus water returned -- +42.95 m3 world-eq deprived on every withdrawal, -42.95 on every return to water, its 209 regional factors written on those flows -- and lists Water to air without characterising it. The ecoinvent Centre counts the same consumption as what evaporates: withdrawals and returns at zero and the 42.95 on Water to air. On a water-balanced dataset the two agree, because the vapour is the withdrawn water that was not returned. This list published both -- ecoinvent's air factor came in as restated, because 42.95 stands bit for bit on every withdrawal and that is what the identity twin looks for -- and so counted every consumed cubic metre twice: over 500 ecoinvent 3.12 datasets, water use was 2.00x ecoinvent's at the median. The ruling in lcia-factor-rulings.json declines the air factor and follows the JRC, whose convention is the one the regional factors are written in.

Expectations

4
What should be true State About
Water vapour to air carries no Water use factor of this list's
0749-water-vapour-carries-no-water-use-factor

Published as restated at 42.95 on the 25 August 2026 build (lcia_runs 8660106f), in this and four more air compartments. A ruling is consulted before a proposed row is held for restating, so a decline is what stops the twin from vouching for it.

met factor
flow_name: Water vapour
context_display: Environmental → Air → Unknown
category: Water use
implemented_by: brightway-flows
Water withdrawn still carries the JRC's Water use factors
0749-the-withdrawal-still-carries-it

The ruling takes one convention, not both away. The withdrawal keeps its 42.95 for no particular place and its 209 regional factors, the return to water keeps its -42.95, and the vapour alone is declined. Existence rather than the amount, because a factor subject selects every geography of the flow and 210 rows carry 210 numbers.

met factor
flow_name: Water
context_display: Resource → Water → Unknown
category: Water use
implemented_by: brightway-flows
The ecoinvent Centre's 42.95 for water vapour is still published under their name
0749-the-ecoinvent-centre-still-says-so

A decline withholds this list's number and erases nobody's. Their reading of the method is valid; it is publishing it beside the JRC's that is not.

met factor
flow_name: Water vapour
context_display: Environmental → Air → Unknown
category: Water use
implemented_by: ecoinvent Centre (3.12)
At least four proposed-factor questions are answered by a ruling
0749-the-proposed-question-is-answered

Three before this ruling -- the pool credit's two (#139) and carnallite (#148) -- and four with it. Bounded below, as #148's is, because the count is the queue's.

met measure
key: factors.ef_consensus_proposed-factor_items_ruled
value_when_absent: 0

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close