Brightway Flows 1.2.0
GitHub
Issue
#774
Stated in
expectations/0774-coal-mine-off-gas-is-characterised.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

Coal mine off-gas is the methane that desorbs from a seam as it is cut, captured and burned. EF 3.1 lists the flow and characterises it in no category: the JRC's Resource use, fossils rule -- "the CF is equal to 1 for all fossil resources", EUR 29600 §4.10 -- is applied to EF's Non-renewable energy resources from ground, whose six flows are all in megajoules, and EF files mine off-gas one bucket over among the Non-renewable material resources from ground, in standard cubic metres, where Resource use, minerals and metals prices crustal elements in kg Sb-eq and has nothing to price a methane flow from. A fossil fuel falls between two indicators. The ecoinvent Centre states 36 MJ/Sm³ for it, which is the JRC's rule times this flow's heating value, and a publish ruling in lcia-factor-rulings.json adopts it -- the same ground #155's minerals were approved on. Unlike horticultural peat (#160), where EF's filing is a decision, here it is a gap.

Expectations

4
What should be true State About
Coal mine off-gas carries a Resource use, fossils factor of 36 per standard cubic metre
0774-coal-mine-off-gas-carries-a-fossil-factor

Published as derivation: ruled from the ecoinvent Centre's statement. The number is the JRC's own rule arithmetic: 1.0 MJ per MJ, times 36 MJ per standard cubic metre, which ecoinvent's implementation report (v3.12, Table 6) gives as this flow's lower heating value -- the same it gives natural gas.

met factor
flow_name: Gas, Mine, Off-gas, Process, Coal Mining
context_display: Resource → Ground
category: Resource use, fossils
implemented_by: brightway-flows
Coal mine off-gas is still published in standard cubic metres
0774-the-flow-keeps-its-unit

The ruling publishes a number on the flow as EF ships it rather than converting the flow to megajoules so that a 1.0 could reach it. Converting would restate a unit EF publishes and which the merge records deliberately (#141), and would say nothing the 36 does not.

met flow
name: Gas, Mine, Off-gas, Process, Coal Mining
unit: sm3
The six energy carriers EF characterises still carry 1.0 megajoule per megajoule
0774-the-energy-carriers-are-untouched

Adopting a number for a seventh flow does not change the six the JRC states. Natural gas stands for the family here because it is the flow whose heating value mine off-gas shares, so a change that confused the two would show up on it.

met factor
flow_name: Natural Gas
context_display: Resource → Ground
category: Resource use, fossils
implemented_by: brightway-flows
At least eight proposed-factor questions are answered by a ruling
0774-the-proposed-question-is-answered

Six on the 25 August 2026 build, seven with the peat decline (#160), eight with this. Bounded below, as the earlier ones are, because the count is the queue's and an answer to some other question should not fail a claim about this one.

met measure
key: factors.ef_consensus_proposed-factor_items_ruled
value_when_absent: 0

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close