Brightway Flows 1.2.0
GitHub
Issue
#784
Stated in
expectations/0784-greendelta-reaches-a-flow-by-its-substance.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

GreenDelta's openLCA package identifies a flow by the ecoinvent UUID it was built against, and 1,223 of its 1,781 flows are found that way. The other 558 name a substance under an identifier nothing here has -- and none of them is a substance this list is missing. This is the second route: the substance, in the compartment the factor is about.

**A substance and a place, never a substance alone.** A factor is a number about a substance in a compartment, so a match needs both halves; reaching a flow by name and letting the compartment fall where it may would put a freshwater number on an emission to air, which is a wrong factor rather than a missing one. The compartments are 21 curated rows in data/context-manual-mapping.json under the source GreenDelta, each recording the evidence it was written from.

**The registry number outranks the name.** #146 and #157 are both cases where a name and a number disagreed and the number was right. Where two flows carry one number -- Water and Water vapour both carry 7732-18-5 -- the name settles which, and only settles: it narrows what the number chose and never reaches outside it. Where nothing settles it, the row is reported and matched to neither.

Measured on the build of 2026-08-25 (20260825T1354430622920000) characterised 2026-08-28: 307 more flows reached, 1,166 more factors published, and the consensus implementation unmoved. The consensus count itself was re-measured for #349 on the full build of 2026-08-29 (20260829T1158418340740000), where it is 323,890 rather than 324,694 for a reason that is the JRC's and not GreenDelta's. Every claim below fails on main and on the branch that added the implementation, where the second route does not exist.

Expectations

4
What should be true State About
307 flows no identifier reaches are found by their substance
0784-the-second-route-reaches-three-hundred-flows

289 on a registry number alone, 2 on a number two flows carry with the name settling which, and 16 on a name where their file states no number. The identifier route is not reconsidered: it reached 1,223 and those are not re-decided on a weaker claim.

met measure
key: factors.ef_greendelta_source_flows_by_substance
GreenDelta's published factors rise to 23,508
0784-the-factors-those-flows-carry

22,342 before, of the 26,179 their file states. The remaining 2,671 are the 1,711 in the three resource compartments this list files as a context rather than a name (#166), 235 on flows whose substance is not published in the compartment the factor is about, and the rest the regionalised water rows -- Water, DK and 56 others -- whose place is in their name and in nothing of ours. at_least, because #166 should raise it.

met measure
key: factors.ef_greendelta_factors_published
A row whose number reaches two flows is reported, not placed on one
0784-a-number-two-flows-carry-is-not-guessed-at

The tie-break, and the number is small because it is meant to be: 52 rows state 7732-18-5 in a compartment where Water and Water vapour both sit, and only the two whose name is exactly one of ours are placed. The other 50 carry a country in the name -- Water, DK -- which no label of ours does, and are left unmatched with a finding naming both candidates. A claim about what the rule *declines* to do, held as the count of the only case where a name is allowed to act on a number's candidates.

met measure
key: factors.ef_greendelta_matched_on_registry_number_and_name
A lake factor reaches the flow it is about, in the compartment it was stated in
0784-a-lake-factor-reaches-its-flow

Emission to water/lake is one of the compartments ecoinvent 3 does not have, so no flow of theirs resolves in it by identifier and the rule for it rests on BAFU's evidence: 50 of BAFU's rows, every one in Environmental -> Water -> Lake. Fluoride reaches this flow on its registry number and 20.361 is GreenDelta's own number republished unchanged. Named Fluoride(1-) since #401 gave every anion its charge number; Fluoride until then. Before this change every lake row of theirs was dropped, so the whole compartment was missing from the comparison rather than differing in it.

met factor
flow_name: Fluoride(1-)
context_display: Environmental → Water → Lake
category: Ecotoxicity, freshwater
implemented_by: GreenDelta

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close