Brightway Flows 1.2.0
GitHub
Issue
#789
Stated in
expectations/0789-greendelta-ionic-names-are-a-curated-table.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

GreenDelta writes 25 of their flows under a spelling for an ion no published label of ours matches -- Copper ion where this list publishes Copper, Ion, Cadmium II where it publishes Cadmium(2+) -- and states no registry number for any of them, so #165's rule reaches them by neither of its routes. 107 factors, and not one of them is about a substance this list is missing.

**Their own package says which substance each name means.** Each of these names appears in their file once per compartment, nine to thirteen times, and most of those copies carry an ecoinvent uuid that already resolves -- to Copper, Ion seven times out of twelve, to Cadmium(2+) ten times out of twelve, and never to a second substance of ours. data/lcia-substance-decisions.json carries that reading into the compartments where their identifier does not resolve, one row per flow of theirs, each recording the count it rests on.

**Seven of the 25 are declined, and that is a decision rather than a gap.** They are metals emitted to a lake, and Environmental -> Water -> Lake publishes 42 flows, all BAFU's, naming a dissolved metal for its element: Cadmium, with no Cadmium(2+) beside it. This list keeps the two apart in all four water contexts where both exist. Declining costs no number -- every value those rows state is stated again by their own fresh water, ground water or unspecified row, and those reach the ionic flow -- and the finding that reports each one carries the reasoning from the file.

Measured on the build of 2026-08-25 (20260825T1354430622920000) characterised 2026-08-29: 18 more flows reached, 69 more factors published, and the consensus implementation unmoved. The consensus count is re-measured for #349 on the full build of 2026-08-29 (20260829T1158418340740000), where it is 323,890. Every claim below fails on #165's branch, where the table does not exist.

Expectations

6
What should be true State About
18 flows no number and no name reaches are found by a curated decision
0789-the-table-reaches-eighteen-flows

Its own basis beside registry-number, registry-number-and-name and name, because "a curator read the publisher's package and said so" is a different strength of claim from "the number agreed", and a reader deciding whether to trust a factor has to be able to tell them apart. The other three are unchanged at 289, 2 and 16: the table adds a route and takes nothing from the ones that already worked.

met measure
key: factors.ef_greendelta_matched_on_curated_decision
The nine declined rows reach nothing, and the build says it was decided
0789-seven-rows-are-declined-on-purpose

An equality, because this is the count of a decision and not of a shortfall. Growing means something new was refused and nobody wrote it down here; shrinking means one of the nine found a flow, which for the seven would be Water -> Lake gaining an ionic metal and is a reason to re-read the decision rather than to let it lapse quietly. Each of the nine gets exactly one flow-not-reached finding carrying declined_because -- the row reached nothing, which is one thing that happened. Seven of the nine are this issue's lake rows. The other two are #350's: Platinum and Uranium under Resource / unspecified, declined because both numbers are already published on Resource -> Ground from the copy of theirs that arrived with an identifier, and a compartment that names no place gives no reason to prefer this copy. The bound counts declines rather than lake rows, so it moves whenever another list's row is refused on the record, and 9 is what the four-list build of 2026-08-29 (20260829T1631159082840000) states.

met measure
key: factors.ef_greendelta_source_flows_declined
GreenDelta's published factors rise to 23,577
0789-the-factors-those-flows-carry

23,508 before, of the 26,179 their file states. The 69 added are the 18 decided rows' own factors and nothing else. The 38 on the seven declined rows stay unpublished, and the rest of the 2,602 remaining are #166's 1,711 in the three resource compartments this list files as a context, the regionalised Water, DK rows whose place is in their name, and the ties and unit crossings #165 reports. at_least, because #166 should raise it.

met measure
key: factors.ef_greendelta_factors_published
GreenDelta characterises 1,456 of this list's flows
0789-eighteen-more-flows-are-characterised

1,438 before. Eighteen rows, eighteen flows: no two of the 25 name one flow of ours in one compartment, which is what makes each of them a decision about a row rather than a rule about a name.

met measure
key: factors.ef_greendelta_flows_characterised
GreenDelta's Aluminium III resource factor agrees with the JRC's to the digit
0789-the-aluminium-resource-row-agrees

The row whose name and compartment disagree: they call it Aluminium III and file it under Resource/in ground, and aluminium in the ground is the element rather than a dissolved ion. The number is what settles it. 1.09e-09 is exactly what the JRC and the ecoinvent Centre both state for this flow, and what the consensus already publishes as agreed; their twelve other flows of this name are all emissions and all reach Aluminium(3+), which is not published in a resource compartment. One factor, and it is here because it is the one row in the table decided by a number rather than by a count of their own resolutions. Before this change it was dropped, so a third implementation agreeing was invisible.

met factor
flow_name: Aluminium
context_display: Resource → Ground
category: Resource use, minerals and metals
implemented_by: GreenDelta
Arsenic V reaches arsenate and Arsenic ion reaches the unspeciated ion
0789-arsenic-keeps-its-two-substances-apart

Their file ships Arsenic V and Arsenic ion as two flows in this one compartment, so they mean two substances, and this list publishes both -- Arsenic(5+) and Arsenic, Ion -- in it. 2506.95 is the arsenate row's number; the unspeciated row states 1725.896653 in the same compartment and category and reaches Arsenic, Ion. The claim is that the table does not collapse them. Arsenic V is the one name in the 25 that resolves nowhere in their own package, so nothing of theirs settles it and a looser rule -- anything that read Arsenic ion as arsenic in some oxidation state -- would have taken both rows to one flow and lost a number.

met factor
flow_name: Arsenic(5+)
context_display: Environmental → Ground → Industrial
category: Ecotoxicity, freshwater
implemented_by: GreenDelta

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close