Brightway Flows 1.2.0
GitHub
Issue
#885
Stated in
expectations/0885-one-water-vapour-flow-in-unspecified-air.json
Graded against
Statuses are those of the build recorded on 2026-11-24 07:55 UTC (run 20261124T0755302069730000, merging ecoinvent-3.13, ecoinvent-3.12, ecoinvent-3.8, bafu-2026-v1, stepwise-2006-1.09, agribalyse-3.2).

Why this file exists

EF 3.1 publishes water vapour twice in unspecified air, in cubic metres: Water (0342f5e5-...) bare, and Water (evapotranspiration) (4b772bba-...) carrying EF's remark that it is water vapour, but coming from growing renewables. Same substance object, same context, same unit, no factor on either, and the collision queue reports the pair with general_comment as the only differing field. Every mapping that exists lands on the bare row -- ecoinvent's correspondence tables in both merged releases, and AGRIBALYSE's Water/m3 override (#353), which had to pick between the pair per row because nothing on a source row can prefer one spelling of the same thing over the other. #191 rules the pair one flow in elementary-flow-collision-decisions.json: the bare row survives, the evapotranspiration row is deprecated onto it with EF's remark kept in the ruling. These claims are false of every build before the ruling -- the 1 September 2026 shared build holds both rows live -- and true of the first build after it.

Expectations

3
What should be true State About
Water vapour is published once in unspecified air in cubic metres, not twice
0885-one-cubic-metre-vapour-flow-in-unspecified-air

Two live flows on every build up to 1 September 2026 (run c5445e95). The kilogram flow in the same context is a different unit and is deliberately outside this claim; selecting by name and context alone would count it and hide a change in the pair behind a change in the kilograms.

met flow
name: Water vapour
context_display: Environmental → Air → Unknown
unit: m3
The surviving cubic-metre flow is the one every correspondence and override names
0885-the-surviving-flow-is-the-one-every-list-reaches

ecoinvent 3.8's and 3.12's bare Water m3 rows reach this flow through their correspondence tables, and AGRIBALYSE's Water/m3 is sent here by its override (#353). A ruling that collapsed the pair the other way would strand all of them on a deprecated flow, which is what tests/test_collision_rulings_ecoinvent.py exists to make impossible.

met flow
uuid: 0342f5e5-b53e-4cec-9e67-fb197f24fff0
EF's evapotranspiration copy is deprecated onto the survivor rather than deleted
0885-the-evapotranspiration-copy-redirects-to-the-survivor

Deprecated, not removed: EF's identifier stays resolvable and redirects, so a consumer holding the evapotranspiration uuid finds the surviving flow, and EF's origin remark -- the one thing that ever told the pair apart -- survives on the ruling and on this row's deprecation comment. If a water model ever needs evapotranspirated vapour as its own flow, this row and #191 are where that discussion picks up.

met flow
uuid: 4b772bba-b5c1-4098-9c1d-3d9d8c74c7fa
include_deprecated: yes

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close