Brightway Flows 1.0
GitHub

Identity

Substance
fo-984e2d1aad246ca6 Imprecise chemical mixture
Source
EF 3.1
Unit
kg
Context
Environmental → Air → Unknown
CAS
84011-06-3
EC

Context

Dimension
Environmental
Media
Air
Strata
Unknown

Source lists

2
List Version Source flow Name there Why this flow
EF 3.1 8dff2c37-68b1-46c6-84bb-5dcc26445209 HFE-236fa The consensus list is built from this one, so this row is the flow itself rather than something matched to it.
stepwise 2006-1.09 489d72bc-a588-588f-b933-bee6271f29a0 Ether, 1,2,2-trifluoroethyl trifluoromethyl-, HFE-236fa Several substances share the CAS number (84011-06-3), and the industry designation the row's name ends in names this one; both name the same compartment.

Concept associations

2
Source list Source flow Name there Compartment there Match Conversion
EF 3.1 8dff2c37-68b1-46c6-84bb-5dcc26445209 HFE-236fa Emissions/Emissions to air/Emissions to air, unspecified exactMatch
stepwise 2006-1.09 489d72bc-a588-588f-b933-bee6271f29a0 Ether, 1,2,2-trifluoroethyl Trifluoromethyl-, HFE-236fa Air / (unspecified) closeMatch

Characterisation factors

6

Every implementation that says anything about this flow. Published as is what this list did with the row: where more than one implementation states a number and they agree it publishes it as agreed; where only one speaks, as sole; where they disagree it publishes nothing and asks.

Method Implementation Category Place Factor Published as
EF 3.1 European Commission — JRC Climate change 1,100
EF 3.1 consensus-flow-list Climate change 1,100 sole
EF 3.1 European Commission — JRC Climate change-Fossil 1,100
EF 3.1 consensus-flow-list Climate change-Fossil 1,100 sole
Stepwise 2006 2.-0 LCA consultants Global warming, fossil 1,260
Stepwise 2006 consensus-flow-list Global warming, fossil 1,260 sole

This flow in the difference report

History

The change log and the PROV-O trail (1 consensus changes)

Open the changes page

These are the heaviest sections of this page and the least often read, so the page does not pay for them until you ask.

Full record

Flow JSON
{
  "altLabel": [],
  "properties": {},
  "references": [
    {
      "@id": "https://commonchemistry.cas.org/detail?cas_rn=84011-06-3",
      "provenance": {
        "prov:wasGeneratedBy": "enrich_references.consensus_cas_link",
        "prov:wasAttributedTo": "consensus-flow-list",
        "prov:hadPrimarySource": [
          "84011-06-3"
        ],
        "prov:wasDerivedFrom": "cas_numbers"
      }
    }
  ],
  "prefLabel": [
    {
      "@value": "HFE-236fa",
      "@language": "en",
      "source": {
        "prov:wasGeneratedBy": "bootstrap_labels",
        "prov:wasAttributedTo": "consensus-flow-list",
        "prov:hadPrimarySource": [
          "EF 3.1"
        ],
        "prov:wasDerivedFrom": "legacy name field"
      }
    }
  ],
  "@type": [
    "https://w3id.org/chemrof/ImpreciseChemicalMixture"
  ],
  "http://www.w3.org/2004/02/skos/core#definition": [],
  "uuid": "8dff2c37-68b1-46c6-84bb-5dcc26445209",
  "identifier": "8dff2c37-68b1-46c6-84bb-5dcc26445209",
  "source": "EF 3.1",
  "cas_numbers": [
    "84011-06-3"
  ],
  "ec_numbers": [],
  "context": {
    "dimension": "Environmental",
    "media": "Air",
    "strata": "Unknown"
  },
  "synonyms": [],
  "lcia_methods": [
    {
      "method_uuid": "6209b35f-9447-40b5-b68c-a1099e3674a0",
      "name": "Climate change",
      "methodology": "Environmental Footprint",
      "impact_category": "Climate change",
      "impact_indicator": "Radiative forcing as Global Warming Potential (GWP100)",
      "characterization_factor": 1100.0
    },
    {
      "method_uuid": "7fce5b3a-66b8-4ce1-91e8-a925aee1f186",
      "name": "Climate change-Fossil",
      "methodology": "Environmental Footprint",
      "impact_category": "Climate change",
      "impact_indicator": "Radiative forcing as Global Warming Potential (GWP100)",
      "characterization_factor": 1100.0
    }
  ],
  "unit": "kg",
  "input_datasets": [
    "EF 3.1"
  ],
  "context_iri": "https://vocab.brightway.one/flow-contexts/envi-air-unkn",
  "unit_iri": "https://vocab.brightway.one/units/unit/KiloGM",
  "flow_object_id": "fo-984e2d1aad246ca6",
  "concept_associations": [
    {
      "@type": "xkos:ConceptAssociation",
      "xkos:sourceConcept": {
        "@id": "https://vocab.brightway.one/ef/3.1/flow/8dff2c37-68b1-46c6-84bb-5dcc26445209",
        "skos:prefLabel": "HFE-236fa",
        "context": "Emissions/Emissions to air/Emissions to air, unspecified",
        "qudt:hasUnit": {
          "@id": "https://vocab.brightway.one/units/unit/KiloGM"
        },
        "skos:exactMatch": {
          "@id": "https://vocab.brightway.dev/elementary-flows/8dff2c37-68b1-46c6-84bb-5dcc26445209"
        }
      },
      "xkos:targetConcept": {
        "@id": "https://vocab.brightway.dev/elementary-flows/8dff2c37-68b1-46c6-84bb-5dcc26445209"
      },
      "provenance": {
        "prov:wasGeneratedBy": "build_concept_associations",
        "prov:wasAttributedTo": "consensus-flow-list",
        "prov:hadPrimarySource": [
          "https://eplca.jrc.ec.europa.eu/permalink/EF3_1/EF-v3.1.zip"
        ]
      }
    },
    {
      "@type": "xkos:ConceptAssociation",
      "xkos:sourceConcept": {
        "@id": "https://vocab.brightway.one/stepwise/2006-1.09/flow/489d72bc-a588-588f-b933-bee6271f29a0",
        "skos:prefLabel": "Ether, 1,2,2-trifluoroethyl Trifluoromethyl-, HFE-236fa",
        "context": "Air / (unspecified)",
        "qudt:hasUnit": {
          "@id": "https://vocab.brightway.one/units/unit/KiloGM"
        },
        "skos:closeMatch": {
          "@id": "https://vocab.brightway.dev/elementary-flows/8dff2c37-68b1-46c6-84bb-5dcc26445209"
        }
      },
      "xkos:targetConcept": {
        "@id": "https://vocab.brightway.dev/elementary-flows/8dff2c37-68b1-46c6-84bb-5dcc26445209"
      },
      "provenance": {
        "prov:wasGeneratedBy": "merge_stepwise",
        "prov:wasAttributedTo": "consensus-flow-list",
        "prov:hadPrimarySource": [
          "stepwise:2006-1.09:489d72bc-a588-588f-b933-bee6271f29a0",
          "Ether, 1,2,2-trifluoroethyl Trifluoromethyl-, HFE-236fa",
          "",
          "algorithm.lookup_order=cas>ec>label",
          "algorithm.basis=cas+designation:84011-06-3",
          "algorithm.flow_object_candidates=1",
          "algorithm.elementary_candidates=11",
          "algorithm.selector_reason=exact-context-iri-match",
          "algorithm.score_rule=exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
        ],
        "prov:wasDerivedFrom": "algorithmic_fallback:lookup_order(cas>ec>label);basis(cas+designation:84011-06-3);flow_object_candidates(1);elementary_candidates(11);selector(exact-context-iri-match);exact-iri-shortcircuit;up-tree-filter;score=(2*unit_exact)+context_overlap-context_penalty+context_iri_exact;contradiction-veto"
      }
    }
  ],
  "_sources": {
    "prefLabel": "bootstrap_labels",
    "name": "bootstrap_labels",
    "synonyms": "bootstrap_labels",
    "context": "default_context_mapping",
    "context_iri": "default_context_mapping",
    "unit_iri": "unit_normalization",
    "skos_definition": "enrich_references",
    "references": "enrich_references",
    "cas_match_labels": "consensus_match",
    "concept_associations": "carry_associations_onto_flows",
    "types": "link_flows_to_their_substance"
  },
  "cas_match_labels": {
    "84011-06-3": "exactMatch"
  },
  "general_comment": "Note that this substance has two isomers with different impact factors, but registered under the same CAS. Separate elementary flows are available. Reference elementary flow of the International Reference Life Cycle Data System (ILCD).",
  "_transformed": true,
  "_provided": {
    "name": "HFE-236fa",
    "synonyms": [
      "ether, 1,2,2-trifluoroethyl trifluoromethyl-",
      "Ether, 1,2,2-trifluoroethyl trifluoromethyl-, HFE-236fa"
    ],
    "context": [
      "Emissions",
      "Emissions to air",
      "Emissions to air, unspecified"
    ],
    "cas_numbers": [
      "84011-06-3"
    ],
    "ec_numbers": [],
    "unit": "kg"
  }
}

Something wrong here?

A flow can be wrong in three ways, and they are decided differently. Pick the one that matches what you are looking at.

You do not need to run a build or clone anything. Name the row and say what your evidence is; the measurement is done for you. How contributing works

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close