Gas, Natural
4e0fae84-bad2-5378-9a09-0d5b6ff09550
agribalyse 3.2
prepared- Name
- Gas, Natural
- Context
- Resources → in ground
- Unit
- m3
- CAS
- 8006-14-2
- EC
- —
- Method
- prepared
- Substance
- fo-634eaeddc2496342
- Target flow
- fe0acd60-3ddc-11dd-a6fa-0050c2490048
Everything this outcome recorded
{
"source_uuid": "4e0fae84-bad2-5378-9a09-0d5b6ff09550",
"source_name": "Gas, Natural",
"source_context": [
"Resources",
"in ground"
],
"source_context_iri": "https://vocab.brightway.one/flow-contexts/reso-grou",
"source_unit": "m3",
"source_cas": "8006-14-2",
"target_elementary_flow_id": "fe0acd60-3ddc-11dd-a6fa-0050c2490048",
"prepared_target_elementary_flow_id": "fe0acd60-3ddc-11dd-a6fa-0050c2490048",
"target_flow_object_id": "fo-634eaeddc2496342",
"target_name": "Natural Gas",
"target_context": [
"Resource",
"Ground"
],
"target_unit": "MJ",
"prepared_target_resolution": "direct-active-target",
"prepared_target_trace": [
"fe0acd60-3ddc-11dd-a6fa-0050c2490048"
],
"prepared_context_decision": "mapped",
"provenance": {
"prov:wasGeneratedBy": "merge_agribalyse",
"prov:wasAttributedTo": "brightway-flows",
"prov:hadPrimarySource": [
"agribalyse:3.2:4e0fae84-bad2-5378-9a09-0d5b6ff09550",
"Gas, Natural",
""
],
"prov:wasDerivedFrom": "randonneur_replace_table:prepared_mapping"
},
"conversion_factor": 34.5,
"conversion_comment": "`Gas, natural/m3`, m3, in `Resources / in ground`, onto EF 3.1's `Natural Gas` in MJ at 34.5 MJ/m3. AGRIBALYSE states the number itself: the substance section at the end of `AGB32_final.CSV` gives this flow a lower heating value (LHV) of 34.5 MJ/m3 and a higher heating value (HHV) of 38.3 MJ/m3. The net value is used because EF 3.1's fossil resource indicator counts energy on a net basis,. It is AGRIBALYSE's number rather than the one ecoinvent's or BAFU's identical rows carry onto this target (36.0 MJ per standard cubic metre for ecoinvent 3.12 and BAFU); it is also exactly the 34.5 MJ per cubic metre ecoinvent 3.8, the background database AGRIBALYSE 3.2 is built on, states for its own `m3` natural gas (#777), because the vendor has said what its own kilogram holds, the same reasoning that already gives `Wood and wood waste, 9.5 MJ per kg` the number in its name; whether every list should convert by its own value is #407. The busiest of the 26: `Road vehicle factory {GLO}` alone takes 16,722,321 m3 of it, which without this number was published as 16.7 million MJ, 34.5 times too little. On the first five-list full build (2 September 2026, `944b274`) the row reached this flow by itself with no number on the mapping, and so published its amount in the wrong unit (#370)."
}