Scores › ecoinvent 3.12 cutoff
electricity, high voltage, import from IN-North-eastern grid IN-Eastern grid
1 kilowatt hour of electricity, high voltage; an inventory of 2,771 flows, of which 2,771 reached a consensus flow and 0 did not.
f168770b-62a2-5b5e-bbf2-ac3bc1ce7d09 · brightway 1850f089a233c05d421ff3737144186d · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
0.002822 | 0.002822 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
0.832683 | 0.832687 | 1.000 | within tolerance | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
7.9470e-04 | 7.9470e-04 | 1.000 | identical | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
0.826579 | 0.826583 | 1.000 | within tolerance | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
0.005309 | 0.005309 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
2.343124 | 2.343112 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
2.132388 | 2.132388 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.210736 | 0.210724 | 1.000 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
12.46267 | 12.462647 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg P-Eq
|
1.4448e-04 | 1.4448e-04 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
6.0232e-04 | 6.0232e-04 | 1.000 | within tolerance | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
0.006244 | 0.006244 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
1.1249e-10 | 1.1249e-10 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
3.0214e-11 | 3.0214e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
8.2271e-11 | 8.2271e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
2.5456e-09 | 2.5456e-09 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
2.4046e-09 | 2.4046e-09 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
1.4100e-10 | 1.4100e-10 | 1.000 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.002639 | 0.002639 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
0.590402 | 0.590402 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
4.0798e-07 | 4.0797e-07 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
1.7121e-08 | 1.7189e-08 | 1.004 | within tolerance | 0.00 |
|
particulate matter formation
disease incidence
|
1.2616e-08 | 1.2616e-08 | 1.000 | within tolerance | 0.00 |
|
photochemical oxidant formation: human health
kg NMVOC-Eq
|
0.00235 | 0.00235 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world Eq deprived
|
0.233278 | 0.188149 | 0.807 | 2x | 0.00 |
climate change: land use and land use change: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Carbon dioxide, from soil or biomass stock 78eb1859-abd9-44c6-9ce3-f3b5b33d619c |
Carbon Dioxide (land Use Change) | 0.005306 | — | 1 | 1 | 0.005306 | 0.005306 | 0 | agree |