electricity production, lignite IN-WB
1 kilowatt hour of electricity, high voltage; an inventory of 2,771 flows, of which 2,771 reached a consensus flow and 0 did not.
ae7e1a58-6fc2-5e77-864b-c9d36ac018d4 · brightway 2008296eeda6f17674774aef526330ef · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · EcoSpold01Categories: lignite/power plants · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
0.005426 | 0.005426 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
1.434313 | 1.434315 | 1.000 | within tolerance | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
2.7228e-05 | 2.7228e-05 | 1.000 | identical | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
1.434168 | 1.43417 | 1.000 | within tolerance | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
1.1785e-04 | 1.1785e-04 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
5.00582 | 5.005802 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
4.99606 | 4.99606 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.00976 | 0.009742 | 0.998 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
13.341861 | 13.341855 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg P-Eq
|
0.002796 | 0.002796 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
0.001619 | 0.001619 | 1.000 | within tolerance | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
0.011706 | 0.011706 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
3.0816e-10 | 3.0816e-10 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
2.9937e-10 | 2.9937e-10 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
8.7827e-12 | 8.7827e-12 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
1.6252e-08 | 1.6252e-08 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
1.6204e-08 | 1.6204e-08 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
4.8568e-11 | 4.8568e-11 | 1.000 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.002085 | 0.002085 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
4.167724 | 4.167724 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
1.7196e-07 | 1.7196e-07 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
3.2814e-10 | 3.3719e-10 | 1.028 | 2x | 0.00 |
|
particulate matter formation
disease incidence
|
1.3584e-08 | 1.3584e-08 | 1.000 | within tolerance | 0.00 |
|
photochemical oxidant formation: human health
kg NMVOC-Eq
|
0.003026 | 0.003026 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world Eq deprived
|
0.119423 | 0.119001 | 0.996 | within tolerance | 0.00 |
eutrophication: freshwater: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Phosphate 490b267b-f429-4d9a-ac79-224e37fb4d58 |
Phosphate | 0.007592 | — | 0.33 | 0.33 | 0.002505 | 0.002505 | -9.9552e-11 | agree |
| Phosphate 329fc7d8-4011-4327-84e4-34ff76f0e42d |
Phosphate | 8.7954e-04 | — | 0.33 | 0.33 | 2.9025e-04 | 2.9025e-04 | -1.1533e-11 | agree |
| Phosphate 3aaf9017-0d8a-42aa-9a60-cbc39e994e73 |
Phosphate | 7.9202e-09 | — | — | 0 | 0 | 0 | 0 | only consensus factor |
| Phosphorus 62f3d964-9b53-4d01-9ee0-04112dcfc6d2 |
Phosphorus | 3.8925e-12 | — | — | 0 | 0 | 0 | 0 | only consensus factor |