Scores › ecoinvent 3.12 cutoff
electricity, high voltage, import from US-MRO CA-MB
1 kilowatt hour of electricity, high voltage; an inventory of 2,771 flows, of which 2,771 reached a consensus flow and 0 did not.
37a468af-52ff-59f6-b270-767e3feb54af · brightway ecdbe32cf77ee81d2c01dcef39091d76 · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
0.00175 | 0.00175 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
0.480109 | 0.48011 | 1.000 | within tolerance | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
1.5838e-04 | 1.5838e-04 | 1.000 | within tolerance | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
0.479234 | 0.479235 | 1.000 | within tolerance | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
7.1714e-04 | 7.1714e-04 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
1.455723 | 1.455713 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
1.43646 | 1.43646 | 1.000 | within tolerance | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.019263 | 0.019253 | 0.999 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
6.21819 | 6.218179 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg P-Eq
|
7.4585e-04 | 7.4585e-04 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
3.7112e-04 | 3.7112e-04 | 1.000 | within tolerance | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
0.002396 | 0.002396 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
8.3416e-11 | 8.3416e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
7.4591e-11 | 7.4591e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
8.8255e-12 | 8.8255e-12 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
4.2570e-09 | 4.2570e-09 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
4.2137e-09 | 4.2137e-09 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
4.3224e-11 | 4.3224e-11 | 1.000 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.055866 | 0.055866 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
0.561938 | 0.561938 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
3.1728e-07 | 3.1727e-07 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
8.1548e-10 | 8.2429e-10 | 1.011 | within tolerance | 0.00 |
|
particulate matter formation
disease incidence
|
1.1265e-08 | 1.1265e-08 | 1.000 | within tolerance | 0.00 |
|
photochemical oxidant formation: human health
kg NMVOC-Eq
|
7.9474e-04 | 7.9474e-04 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world Eq deprived
|
0.10987 | 0.108926 | 0.991 | within tolerance | 0.00 |
climate change: land use and land use change: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Carbon dioxide, from soil or biomass stock 78eb1859-abd9-44c6-9ce3-f3b5b33d619c |
Carbon Dioxide (land Use Change) | 7.1648e-04 | — | 1 | 1 | 7.1648e-04 | 7.1648e-04 | 0 | agree |
| Carbon dioxide, from soil or biomass stock e4e9febc-07c1-403d-8d3a-6707bb4d96e6 |
Carbon Dioxide (land Use Change) | 1.0186e-06 | — | 1 | 1 | 1.0186e-06 | 1.0186e-06 | 0 | agree |