electricity production, wind, 1-3MW turbine, onshore CA-NT
1 kilowatt hour of electricity, high voltage; an inventory of 2,144 flows, of which 2,144 reached a consensus flow and 0 did not.
b4ba9cc1-f164-448f-9d47-b7c621b5b56c · brightway 6217807d9aaa1e7dfe6256a60a5ee9be · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
1.0600e-04 | 1.0603e-04 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
0.01748 | 0.017019 | 0.974 | 2x | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
3.0391e-05 | 2.4134e-05 | 0.794 | 2x | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
0.017433 | 0.016979 | 0.974 | 2x | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
1.5921e-05 | 1.5828e-05 | 0.994 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
0.654187 | 0.130084 | 0.199 | 10x | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
0.076458 | 0.109516 | 1.432 | 2x | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.020392 | 0.020568 | 1.009 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
0.209032 | 0.209003 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg PO4-Eq
|
7.4768e-06 | 7.4768e-06 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
2.1387e-05 | 2.1319e-05 | 0.997 | within tolerance | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
2.1167e-04 | 2.1167e-04 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
8.4510e-11 | 6.6605e-11 | 0.788 | 2x | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
9.2343e-20 | 4.6604e-11 | 504679640.605 | over 100x | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
2.0001e-11 | 2.0001e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
7.6331e-10 | 6.5821e-10 | 0.862 | 2x | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
1.0790e-10 | 6.3487e-10 | 5.884 | 10x | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
2.3343e-11 | 2.3340e-11 | 1.000 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.001189 | 0.001189 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
0.355537 | 0.355537 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
8.2584e-07 | 8.2584e-07 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
1.3171e-09 | 1.3178e-09 | 1.001 | within tolerance | 0.00 |
|
particulate matter formation
disease incidence
|
1.7026e-09 | 1.7026e-09 | 1.000 | within tolerance | 0.00 |
|
photochemical ozone formation: human health
kg NMVOC-Eq
|
7.5715e-05 | 7.5715e-05 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world eq. deprived
|
0.007228 | 0.008105 | 1.121 | 2x | 0.00 |
ionising radiation: human health: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Radon-222 4ac6979b-55f2-42ae-8d7e-37846e92506c |
Radon-222 | 0.512926 | — | 0.00114 | 0.00114 | 5.8474e-04 | 5.8474e-04 | 2.5968e-11 | agree |
| Radon-222 1551f1cd-7cb7-4f68-a628-cb9301323c7b |
Radon-222 | 0.014388 | — | 0.00114 | 0.00114 | 1.6402e-05 | 1.6402e-05 | 7.2842e-13 | agree |
| Cesium-137 42901ad7-4be5-47d9-82cd-380ca34281c1 |
Cesium-137 | 1.7251e-07 | — | 7.86 | 7.86 | 1.3560e-06 | 1.3560e-06 | -2.3033e-14 | agree |
| Carbon-14 19256c0f-bea8-4e61-9499-8cc2f84953f8 |
Carbon-14 | 5.8291e-05 | — | 10 | 10 | 5.8291e-04 | 5.8291e-04 | 0 | agree |