electricity production, wind, >3MW turbine, onshore CH
1 kilowatt hour of electricity, high voltage; an inventory of 2,144 flows, of which 2,144 reached a consensus flow and 0 did not.
72bdf907-bdd0-42ca-abe5-e50b4d145cd9 · brightway 85ae275af9624116e21564d484c3f4f1 · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
4.2906e-04 | 4.2915e-04 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
0.036736 | 0.035833 | 0.975 | 2x | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
8.8496e-05 | 7.0276e-05 | 0.794 | 2x | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
0.036528 | 0.035645 | 0.976 | 2x | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
1.1931e-04 | 1.1818e-04 | 0.991 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
3.314991 | 0.500753 | 0.151 | 10x | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
0.369466 | 0.472965 | 1.280 | 2x | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.027505 | 0.027788 | 1.010 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
0.409743 | 0.409681 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg PO4-Eq
|
3.2525e-05 | 3.2525e-05 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
5.2729e-05 | 5.2513e-05 | 0.996 | within tolerance | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
5.6862e-04 | 5.6862e-04 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
1.6166e-10 | 1.4388e-10 | 0.890 | 2x | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
2.8574e-19 | 9.9485e-11 | 348166401.097 | over 100x | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
4.4393e-11 | 4.4393e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
4.5061e-09 | 4.2896e-09 | 0.952 | 2x | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
2.2175e-10 | 4.0999e-09 | 18.489 | 100x | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
1.8972e-10 | 1.8972e-10 | 1.000 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.002867 | 0.002867 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
0.430006 | 0.430006 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
7.4294e-06 | 7.4294e-06 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
2.8043e-09 | 2.8058e-09 | 1.001 | within tolerance | 0.00 |
|
particulate matter formation
disease incidence
|
3.9839e-09 | 3.9839e-09 | 1.000 | within tolerance | 0.00 |
|
photochemical ozone formation: human health
kg NMVOC-Eq
|
1.8091e-04 | 1.8091e-04 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world eq. deprived
|
0.015974 | 0.020693 | 1.295 | 2x | 0.00 |
ionising radiation: human health: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Radon-222 4ac6979b-55f2-42ae-8d7e-37846e92506c |
Radon-222 | 1.349954 | — | 0.00114 | 0.00114 | 0.001539 | 0.001539 | 6.8344e-11 | agree |
| Radon-222 1551f1cd-7cb7-4f68-a628-cb9301323c7b |
Radon-222 | 0.03781 | — | 0.00114 | 0.00114 | 4.3103e-05 | 4.3103e-05 | 1.9142e-12 | agree |
| Cesium-137 42901ad7-4be5-47d9-82cd-380ca34281c1 |
Cesium-137 | 3.9550e-07 | — | 7.86 | 7.86 | 3.1086e-06 | 3.1086e-06 | -5.2805e-14 | agree |
| Carbon-14 19256c0f-bea8-4e61-9499-8cc2f84953f8 |
Carbon-14 | 1.2719e-04 | — | 10 | 10 | 0.001272 | 0.001272 | 0 | agree |