market for electricity, high voltage SV
1 kilowatt hour of electricity, high voltage; an inventory of 2,144 flows, of which 2,144 reached a consensus flow and 0 did not.
0a2dfe31-cb6b-4a67-b2b3-dc2dc6de7d49 · brightway ef6506dda424500ba5634b12bdedb02e · ISIC rev.4 ecoinvent: 3510:Electric power generation, transmission and distribution · EcoSpold01Categories: hard coal/power plants · CPC: 17100: Electrical energy
| Category | Vendor | This list | Ours ÷ theirs | Band | Unmapped share |
|---|---|---|---|---|---|
|
acidification
mol H+-Eq
|
0.00318 | 0.00318 | 1.000 | within tolerance | 0.00 |
|
climate change
kg CO2-Eq
|
0.317262 | 0.315425 | 0.994 | within tolerance | 0.00 |
|
climate change: biogenic
kg CO2-Eq
|
3.2285e-04 | 2.5638e-04 | 0.794 | 2x | 0.00 |
|
climate change: fossil
kg CO2-Eq
|
0.316852 | 0.315083 | 0.994 | within tolerance | 0.00 |
|
climate change: land use and land use change
kg CO2-Eq
|
8.6814e-05 | 8.5829e-05 | 0.989 | within tolerance | 0.00 |
|
ecotoxicity: freshwater
CTUe
|
8.335741 | 1.099026 | 0.132 | 10x | 0.00 |
|
ecotoxicity: freshwater, inorganics
CTUe
|
0.682746 | 0.9441 | 1.383 | 2x | 0.00 |
|
ecotoxicity: freshwater, organics
CTUe
|
0.154725 | 0.154927 | 1.001 | within tolerance | 0.00 |
|
energy resources: non-renewable
MJ, net calorific value
|
3.475954 | 3.475978 | 1.000 | within tolerance | 0.00 |
|
eutrophication: freshwater
kg PO4-Eq
|
7.0652e-05 | 7.0652e-05 | 1.000 | within tolerance | 0.00 |
|
eutrophication: marine
kg N-Eq
|
4.8619e-04 | 4.6970e-04 | 0.966 | 2x | 0.00 |
|
eutrophication: terrestrial
mol N-Eq
|
0.005035 | 0.005035 | 1.000 | within tolerance | 0.00 |
|
human toxicity: carcinogenic
CTUh
|
1.1966e-10 | 1.0805e-10 | 0.903 | 2x | 0.00 |
|
human toxicity: carcinogenic, inorganics
CTUh
|
2.4976e-18 | 4.4368e-11 | 17764278.300 | over 100x | 0.00 |
|
human toxicity: carcinogenic, organics
CTUh
|
6.3686e-11 | 6.3686e-11 | 1.000 | within tolerance | 0.00 |
|
human toxicity: non-carcinogenic
CTUh
|
2.0494e-09 | 1.6257e-09 | 0.793 | 2x | 0.00 |
|
human toxicity: non-carcinogenic, inorganics
CTUh
|
4.6242e-10 | 1.5910e-09 | 3.441 | 10x | 0.00 |
|
human toxicity: non-carcinogenic, organics
CTUh
|
3.4812e-11 | 3.4686e-11 | 0.996 | within tolerance | 0.00 |
|
ionising radiation: human health
kBq U235-Eq
|
0.011473 | 0.011473 | 1.000 | within tolerance | 0.00 |
|
land use
dimensionless
|
6.982356 | 6.982356 | 1.000 | within tolerance | 0.00 |
|
material resources: metals/minerals
kg Sb-Eq
|
2.9864e-07 | 2.9864e-07 | 1.000 | within tolerance | 0.00 |
|
ozone depletion
kg CFC-11-Eq
|
3.8923e-08 | 3.8951e-08 | 1.001 | within tolerance | 0.00 |
|
particulate matter formation
disease incidence
|
2.0804e-08 | 2.0804e-08 | 1.000 | within tolerance | 0.00 |
|
photochemical ozone formation: human health
kg NMVOC-Eq
|
0.001384 | 0.001384 | 1.000 | within tolerance | 0.00 |
|
water use
m3 world eq. deprived
|
0.030196 | -0.051257 | -1.697 | incomparable | 0.00 |
ionising radiation: human health: flow by flow
Every flow whose contribution the comparison kept — all that differ, and the agreeing ones above a thousandth of the score — largest gap first. Amounts are per 1 kilowatt hour; where the consensus flow is measured in another unit, × is the conversion the merge recorded and our factor is per that unit.
| Vendor flow | Consensus flow | Amount | × | Their factor | Our factor | Theirs | Ours | Gap | Reason |
|---|---|---|---|---|---|---|---|---|---|
| Radon-222 4ac6979b-55f2-42ae-8d7e-37846e92506c |
Radon-222 | 0.867643 | — | 0.00114 | 0.00114 | 9.8911e-04 | 9.8911e-04 | 4.3926e-11 | agree |
| Radon-222 1551f1cd-7cb7-4f68-a628-cb9301323c7b |
Radon-222 | 0.026493 | — | 0.00114 | 0.00114 | 3.0202e-05 | 3.0202e-05 | 1.3412e-12 | agree |
| Uranium-234 ac98d2a4-4985-49f9-b4e2-fc896ef145b6 |
Uranium-234 | 2.6372e-06 | — | 4.57 | 4.57 | 1.2052e-05 | 1.2052e-05 | -4.5270e-13 | agree |
| Carbon-14 19256c0f-bea8-4e61-9499-8cc2f84953f8 |
Carbon-14 | 0.00104 | — | 10 | 10 | 0.0104 | 0.0104 | 0 | agree |