Brightway Flows 1.0
GitHub
Both state a number 3,577 flow and place pairs under this category
The same number 3,562 99.6% of them, exactly — same float, full precision
Different numbers 15 the rows below
Only European Commission — JRC 35,812 stated here and nowhere in the other's list — a difference of flow lists, not of numbers
Only ecoinvent Centre 923 stated here and nowhere in the other's list — a difference of flow lists, not of numbers
Band All 15 Incomparable 0 Outside tolerance 12 Within tolerance 3
Flow Place European Commission — JRC ecoinvent Centre Apart Published
Kresoxim-methyl
Environmental → Ground → Unknown
4.5599e-10 1.7644e-08 39×
100x
ecoinvent Centre higher
4.5599e-10
ruled
Kresoxim-methyl
Environmental → Ground → Agricultural
8.5842e-10 3.2731e-08 38×
100x
ecoinvent Centre higher
8.5842e-10
ruled
Kresoxim-methyl
Environmental → Air → Medium stack, <150 meters → Rural (<1000 people/square mile)
1.9607e-07 2.2942e-08 8.55×
10x
European Commission — JRC higher
1.9607e-07
ruled
Kresoxim-methyl
Environmental → Water → Unknown
1.5727e-07 2.2034e-08 7.14×
10x
European Commission — JRC higher
1.5727e-07
ruled
Kresoxim-methyl
Environmental → Water → Surface water
3.1009e-07 4.3635e-08 7.11×
10x
European Commission — JRC higher
3.1009e-07
ruled
Kresoxim-methyl
Environmental → Air → Unknown
2.3800e-07 5.7725e-08 4.12×
10x
European Commission — JRC higher
2.3800e-07
ruled
Fenpropimorph
Environmental → Ground → Agricultural
9.0515e-06 2.8353e-06 3.19×
10x
European Commission — JRC higher
queued
Fenpropimorph
Environmental → Ground → Unknown
4.6628e-06 1.7237e-06 2.71×
10x
European Commission — JRC higher
queued
Mecoprop
Environmental → Ground → Agricultural
7.5092e-06 1.3569e-05 1.81×
2x
ecoinvent Centre higher
queued
Mecoprop
Environmental → Ground → Unknown
5.2345e-06 8.0496e-06 1.54×
2x
ecoinvent Centre higher
queued
Paraquat
Environmental → Water → Unknown
2.8678e-06 3.2504e-06 1.13×
2x
ecoinvent Centre higher
queued
Paraquat
Environmental → Water → Surface water
5.7333e-06 6.4975e-06 1.13×
2x
ecoinvent Centre higher
queued
Carbon tetrachloride
Environmental → Air → Medium stack, <150 meters → Rural (<1000 people/square mile)
7.8354e-06 7.8400e-06 1.0006×
within tolerance
ecoinvent Centre higher
7.8354e-06
agreed
Carbon tetrachloride
Environmental → Air → Ground level → Urban (>1000 people/square mile)
8.3428e-06 8.3400e-06 1.0003×
within tolerance
European Commission — JRC higher
8.3428e-06
agreed
Carbon tetrachloride
Environmental → Air → Unknown
8.0891e-06 8.0900e-06 1.0001×
within tolerance
ecoinvent Centre higher
8.0891e-06
agreed

This category in the whole-method difference report — every implementation that states a row, banded by the widest pair among them.

Keyboard

?
Show or hide this map
/
Focus search
Esc
Close